Fish VTG (Vitellogenin) ELISA Kit
€0.00
In stock
SKU
ELK8791
Catalog Number: ELK8791
Reactivity: Fish
Standard Range: 31.25-2000 pg/mL
Sensitivity: 9.34 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Fish
Standard Range: 31.25-2000 pg/mL
Sensitivity: 9.34 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with VTG(Vitellogenin) protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to VTG(Vitellogenin). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of VTG(Vitellogenin) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cancer, leukopenia
Alternative Names:
vtg1, Vitellogenin, VTG,
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with VTG(Vitellogenin) protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to VTG(Vitellogenin). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of VTG(Vitellogenin) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cancer, leukopenia
Alternative Names:
vtg1, Vitellogenin, VTG,
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review