General LTA4 (Leukotriene A4) ELISA Kit
€0.00
In stock
SKU
ELK8074
Catalog Number: ELK8074
Reactivity: General
Standard Range: 156.25-10000 pg/mL
Sensitivity: 46.3 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: General
Standard Range: 156.25-10000 pg/mL
Sensitivity: 46.3 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Leukotriene A4(LTA4) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leukotriene A4(LTA4). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leukotriene A4(LTA4) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Infection immunity, Autoimmunity,
Alternative Names:
LT-A4
Sample Type:
serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 10000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Leukotriene A4(LTA4) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leukotriene A4(LTA4). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leukotriene A4(LTA4) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Infection immunity, Autoimmunity,
Alternative Names:
LT-A4
Sample Type:
serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 10000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
Is Featured? | No |
---|