Pseudomonas aeruginosa PCR Kit CE/IVD
€0.00
In stock
SKU
RealCycler PAER-
Catalog Number: RealCycler PAER-
1 Intended use:
RealCycler PAER is an in vitro diagnostic kit of reagents which allows real-time PCR qualitative detection of DNA from Pseudomonas aeruginosa in clinical samples.
The system includes an internal control CHIC (Competitive Heterologous Internal Control) to prevent false negatives due to reaction inhibition.
2 Principle of the test
The polymerase chain reaction (PCR) is based on the amplification of a specific region of the DNA/RNA by using complementary primers to the target sequence. Real-time PCR uses marked probes with fluorophores that emit fluorescence in the case of amplification. The cycle of the PCR protocol in which appears significant fluorescence is proportional to the DNA/RNA quantity present in the sample. This value is called Cycle Threshold (Ct) or Cycle Quantification (Cq).
The amplification of Pseudomonas aeruginosa is detected in the corresponding channel of FAM fluorophore and the internal control is detected in the corresponding channel of Alx532 or HEX fluorophore.
3 Technical specifications
Sensitivity: Pseudomonas aeruginosa: 100 copies/μL.
The analytical sensitivity has been determined by limit dilution. This sensitivity has been showed in repeated assays with reproducibility over 95%.
Specificity: Pseudomonas aeruginosa: hcp gene.
4 Contents
RealCycler PAER includes the AmpliMixand a P. aeruginosa DNA Positive Control.
All reagents are ready to use without adding or rebuilding any component.
RealCycler PAER is an in vitro diagnostic kit of reagents which allows real-time PCR qualitative detection of DNA from Pseudomonas aeruginosa in clinical samples.
The system includes an internal control CHIC (Competitive Heterologous Internal Control) to prevent false negatives due to reaction inhibition.
2 Principle of the test
The polymerase chain reaction (PCR) is based on the amplification of a specific region of the DNA/RNA by using complementary primers to the target sequence. Real-time PCR uses marked probes with fluorophores that emit fluorescence in the case of amplification. The cycle of the PCR protocol in which appears significant fluorescence is proportional to the DNA/RNA quantity present in the sample. This value is called Cycle Threshold (Ct) or Cycle Quantification (Cq).
The amplification of Pseudomonas aeruginosa is detected in the corresponding channel of FAM fluorophore and the internal control is detected in the corresponding channel of Alx532 or HEX fluorophore.
3 Technical specifications
Sensitivity: Pseudomonas aeruginosa: 100 copies/μL.
The analytical sensitivity has been determined by limit dilution. This sensitivity has been showed in repeated assays with reproducibility over 95%.
Specificity: Pseudomonas aeruginosa: hcp gene.
4 Contents
RealCycler PAER includes the AmpliMixand a P. aeruginosa DNA Positive Control.
All reagents are ready to use without adding or rebuilding any component.
Is Featured? | No |
---|