Simian FSH (Follicle Stimulating Hormone) ELISA Kit
€0.00
In stock
SKU
ELK8064
Catalog Number: ELK8064
Reactivity: Simian
Standard Range: 3.13-200 ng/mL
Sensitivity: 0.88 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Simian
Standard Range: 3.13-200 ng/mL
Sensitivity: 0.88 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Follicle Stimulating Hormone(FSH) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Follicle Stimulating Hormone(FSH). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Follicle Stimulating Hormone(FSH) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Reproductive science, Genetic science, Hormone metabolism
Sample Type:
Serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 200 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Follicle Stimulating Hormone(FSH) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Follicle Stimulating Hormone(FSH). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Follicle Stimulating Hormone(FSH) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Reproductive science, Genetic science, Hormone metabolism
Sample Type:
Serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 200 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
Is Featured? | No |
---|
Write Your Own Review